Description

Minew MBM01 0043 is a battery-powered extender. Extenders are used to extend the range and number of node connections in a network. The device is powered by 4 replaceable Lithium batteries (ER14505/AA size, one set installed/included). Depending on configuration and usage, typically between 1 and 5 years battery life can be expected.

This hardware is sourced from Minew. See Minew MBM01 for hardware details.

The Bluetooth chipset is nRF52840 from Nordic Semiconductor.

  • Firmware Model Number: 0x0043
  • Downlinks: Up to 18
  • DFU Type: BLE SMP

Normal Operation Procedure

Similar to all Meshtech extenders the Minew MBM01 0043 is delivered in storage mode. Normal operation device-mode for this device is connected. To increase shelf life and not advertise anything during transport, button press is needed to wake device. Pressing the button for 1s will make device discoverable by advertising BLE storage mode advertisements. Green LED will light to indicate storage mode advertisement started after the 1s button press. Device is now discoverable from nearby systems, generating storage mode events. Command to switch device mode must be sent within 5 minutes. Additional button presses in this state will make green LED blink 3 times and 5 minute timer is extended. If no command to switch device mode is received before timer elapse, device will go back to sleep and require new 1s button press to wake. While device is in connected mode, pressing button will result in LED blinking 3 times. Color of LED blink is depending on connection status. If device has successfully joined a network blue LED will blink, if no connection is established red LED will blink.

Wireless range will depend on many factors and are reduced by obstacles and other devices' wireless interference. Typically around 15m between extenders in an indoor environment - further is possible if line of sight/outdoor/minimal interference, shorter might be required to get trough thick walls/interference.

For best performance it is recommended to follow these rough guidelines when deploying extenders:

  • Start near a gateway.
  • Line of sight or minimal number of obstacles between extenders where possible.
  • Two or more possible uplink devices towards gateway.
  • Avoid mounting so antenna is touching metal.
  • Mount above person height if on wall. Avoid mounting closer than 30cm from ceiling and corner/walls. If mounting on ceiling, avoid mounting closer than 30cm from walls.

Service Mode

Service Mode can be used to perform DFU upgrades and/or factory reset of a device when provisioning information (i.e. network key) is unknown/lost. To enter Service Mode, button need to be pressed while powering on device; in this device's case - while inserting the battery. Note that all 4 batteries need to be removed to power off device, and button need to be pressed while first battery is inserted to enter Service Mode. Device being in Service Mode is indicated by blue LED blinking rapidly. Device is discoverable by "SM" device name while in Service Mode. It runs BLE SMP and can be connected to and upgraded. To perform factory reset, press button continuously for more than 5 seconds while device is in Service Mode. Blue LED will light constant while button is held, and should be held until blue LED turn off (5s) to perform factory reset. If no connection is established or no factory reset command is received, device will reboot and start in previous mode after 2 minute timeout. Timeout is extended while BLE connection is established and for additional 2 minutes after disconnect.

Battery Life

Battery life depends on several factors including, but not limited to:

  • Time the extender performs scanning
  • Number of children connected (central connections)
  • Amount of traffic
  • Number of reconnects
  • Ambient temperature

In Connected Mode with default scan (24%), battery life is up to 1 year. This is the setting recommended when having devices operating in unconnected mode.

Scanning is the factor that impacts battery life the most. In setups where all devices can operate in Connected Mode, Power Saving network mode can be used to greatly increase battery life. See Network Mode for details.

The table below provides some estimates on battery life for some typical conditions/scenarios with low traffic. Scanning 0-5min/hour is typical for Power Saving mode setups, while 60min/hour is equivalent to not having Power Saving active:

Scanning (min/hour) Children Battery Life (years maximum)
0 3 13
0 10 5
0 18 3
5 3 6.4
5 10 3.6
5 18 2.4
60 3 1
60 10 0.9
60 18 0.8

5 min/hour would mean that one device disconnect and is unable to reconnect every hour with network in Power Saving mode. This would be be a quite pessimistic scenario in most installations. If connections are that bad, try to improve the network coverage by moving extenders/sensors or add more extenders.

Note

The scan-window setting will affect battery life and throughput. We highly recommend keeping scan-window at it's default value.

The chemistry in the lithium batteries used in Minew MBM01 makes it difficult to accurately predict remaining capacity without adding additional components consuming energy and increasing cost. Instead of reporting some highly inaccurate value in 0x8100 - Battery Level, the device will report 100 to indicate that voltage is "OK" for most of its operation. Battery Level will then jump to a value < 15 once it knows with high certainty that battery is nearing depletion.

Battery Level has this relation to voltage measured:

VDD mV battery-level
>3300 100
3200-3299 15
3100-3199 14
3000-3099 13
2900-2999 12
2800-2899 11
2700-2799 10
2600-2699 9
2500-2599 8
2400-2499 7
2300-2399 6
2200-2299 5
2100-2199 4
2000-2099 3
1900-1999 2
1800-1899 1
<1799 0

In Scan Network Mode and default settings, it is expected that device will be completely depleted and stop working within one month after first < 15% Battery Level reported.

Device Modes

  • Connected
  • Storage

Properties

Property Reported Default Value From Version
0x8000 - Model Number Yes -
0x8001 - Firmware Version Yes -
0x8002 - Hardware Version Yes -
0x8003 - MAC Address No -
0x8005 - Production Info Extended No -
0x8007 - Variant Yes -
0x8008 - Public Key No -
0x8020 - Power Source Yes 0x02
0x8100 - Battery Level Yes -
0x8101 - Uptime Yes -
0x8110 - Device Mode Yes 0x03
0x8120 - Firmware Update State Yes -
0x8121 - Start Firmware Update - -
0x8122 - Firmware Update Control - -
0x8160 - Ping Counter No 0x0000
0x8201 - Debug No 0x00000000 1.2.0
0x8211 - RSSI Throttling Limit Yes 0x00
0x8212 - Downlink Configuration-2 Yes 0x03000112
0x8230 - General Advertisement reporting No 0x000000
0x8300 - Soft Reset - -
0x8301 - Factory Reset - -
0x8302 - Request Property Reporting - -
0x8303 - Start Upstream Throughput Test - -
0x8305 - Throughput Test Packet Counter No 0x00000000
0x8320 - Destroy Network Below - -
0x8321 - Destroy Network Below Child - -
0x8400 - Performance Counter Reporting Interval Yes 0x0000
0x8401 - Performance Counter Reporting Priority Yes 0x02
0x8850 - EnOcean Config (BETA) Yes 0x0002 1.1.0
0x9000 - Scan Window Yes 0x18 (24 %)
0x9002 - Network Lock Yes 0x00
0x9006 - Preferred Parent Yes 0x000000000000
0x9020 - Offer RSSI threshold (s8) Yes 0x000000000000
0x9100 - Uplink RSSI Yes -
0x9900 - Button 0 Counter Yes -
0xFF00 - Scan Mode - - 1.1.0

Measurements

Measurement From Version
0x8410 - Upstream Packets Sent
0x8411 - Upstream Packets Lost
0x8412 - Downstream Packets Sent
0x8413 - Downstream Packets Lost

Events

Event From Version
0x998000 - Button 0 Pressed
0x8858 - EnOcean PTM 215B Data (BETA) 1.1.0

Release Notes

Release Notes

Licenses