CTHINGS.CO Edge IoT Gateway XS 2032
9.4.0 - 2026-06-18
- Network Protocol: 1.16
- Identifier Dictionary: 16
Added
- Skyresponse support (BETA)
- Wait for NTP sync at startup before starting BLE GW. Wait up to 120 seconds.
- Check NTP sync status on time sync
- Added time jump monitoring. Generate warning if detected. Trigger time sync if time jump is detected.
- On time sync, print time drift (ms and ppm) for previous period (24h) to log
- Added properties:
- 0x8012 - Device Management Enabled
- 0x9817 - Skyresponse Config (BETA)
- 0x8106 - CPU Temperature
Fixed
- Fixed JSON encoding for default-pins-state
9.3.0 - 2026-03-13
- Network Protocol: 1.16
- Identifier Dictionary: 14
Added
- Added backfill support
- Updated MT2 to version 2.4.0
- New reporting topics: timestamped, timestamped-decoded
- New request topics: ack, ack-decoded
- Support for optional secureFlags and networkId in storage-mode-event
9.2.2 - 2026-02-27
- Network Protocol: 1.15
- Identifier Dictionary: 13
Fixed
- Fixed issue where MBE backend API failed to load. This bug was present in versions 9.0.0 to 9.2.1.
9.2.1 - 2026-02-13
- Network Protocol: 1.15
- Identifier Dictionary: 13
Fixed
- Fixed incompatibility issue in secure mode.
9.2.0 - 2026-02-10
This release should not be used, due to an incompatibility issue with older extender versions in secure mode.
- Network Protocol: 1.15
- Identifier Dictionary: 13
Added
- Allow firmware download of block sizes up to 160 byte (typically 128 or 160)
- Added 128-byte block broadcast support
- New optional FLAGS.B128 bit in 0x8124 - Start Firmware Broadcast (explicit override)
- New optional b128 JSON property added to start-firmware-broadcast (v13)
- New property:
- 0x8011 - Device Management Connected
Changed
- Do not abort firmware update (download) unless firmware is confirmed not found
- Made 0x8860 - Salto Config (salto-config) readable (apiKey redacted)
- Increased SHIP (Salto Space) HTTP request timeout from 15s to 30s
- Changed green LED indication
- LED OFF: BLE GW init not complete
- LED ON: BLE GW init complete, management connected
- LED BLINK: GLE GW init complete, management disconnected
- Increase default firmware broadcast interval to 2000 ms in secure mode (still 500 ms in legacy mode)
Removed
- Removed Salto property:
- 0x8861 - Salto Endpoint (BETA)
Fixed
- Reduce chance of firmware updates failing with error 250
- Throttling firmware block traffic correctly for all blocks sizes during firmware update (download)
- Set scan-mode when extender connects to the same route (typically after a reset)
9.1.1 - 2025-12-02
- Network Protocol: 1.14
- Identifier Dictionary: 12
Changed
- Increase MaxCount from 256 to 10000 in Salto requests
9.1.0 - 2025-11-25
Initial release.
- Network Protocol: 1.14
- Identifier Dictionary: 12