Skip to content

Minew B10 V2 0065

2.3.0 - 2026-06-24

  • MT protocol ver.: 1.17

Added

  • Alarm Mode 2. New alarm feature in secure mode to support Skyresponse feature through gateway, or ack from backend.
  • New properties support
    • 0x8127 - Firmware update info.
    • 0x9812 - Alarm state
    • 0x9813 - Clear Alarm State
    • 0x9814 - Skyresponse Alarm Config (BETA)
    • 0x9815 - Ack Alarm State
    • 0x9816 - Ack Alarm Cleared State
  • Do not allow Firmware Update to start again if device firmware-update-state is wait for apply (128) or rebooting shortly (100). Firmware Update has to be aborted before starting new update for these two states.
  • Support faster firmware download in secure mode.
  • Added button sequence to clear alarm manually for Alarm mode 1. 3 long presses, 3 short presses, 3 long presses with less than 10s between each press will manually clear alarm.

Changed

  • Allow to resume firmware download by starting a new download with same version, even after download timeout (240).
  • Max limit of long-button-press-timeout to 8000.
  • Alarm clear timeout to 1 hour, and it will work only in Alarm mode 1.

Fixed

  • Changing property 0x9803 long-button-press-timeout value did not have any effect.
  • Internal bug fixes.

2.2.0 - 2026-03-24

  • Initial release, only internal